Facilitates to test industrial components to enhance the industrial employment skills.
Facilitates easy and safe wiring by students due to use of 4mm sturdy Shrouded banana patch cords & shrouded socket arrangements for high voltage circuits
Each panel has ABS molded plastic sturdy enclosure & colorful screw less overlays showing circuits diagrams & its connection tag numbers for easy understanding & connection
Technical Specifications
Flat Aluminum profile sturdy Modular panel (table top) system, 5X3 modular structure, carrying various high voltage components housed in plastic enclosures (panel) to minimise shock possibility.
Consists of 1 no. of NPN type inductive proximity sensors & defused reflective type proximity sensors operated on 24VDC supply.
Supports One change over type limit Switch with NO & NC contact.
Supports four no of fault windows with flashing indication & Alarm annunciation.
24VDC Power Supply Panel [16 Banana Sockets]
Input 230VAC, output 24VDC/2A. with extenders for connections.
Dual Timer Panel (DTP) [14 Shrouded Banana]
Consists of two nos of Individual Timers 24V DC or 230Vac operated supply coil.
Each Timer Supports 2 NO & 1 NC contacts.
Relay Panel (SEP-03) [16 Banana Sockets]
Consists of 8 nos of change over type relays with NO, NC & Common contacts for each with supplly coil of 24VDC. Supports lamp LED Indication for 8 outputs.
3 Ph. Bidirectional power cum Energy meter panel (EMT20) [8 shrouded Banana]
Bidirectional Multifunction
3 Phase ¾ wire, 415V, CT Input 5A
LCD/LED display, Aux supply 230V, 45-65 Hz, 5W
V,I., Hz, Pf, KVA, KW,KWH
Modbus RTU RS 485 (optional)
Green SBS5 socket is provided for extend earth.
Optional
3 phase AC Squirrel cage foot mounted motor with 6 terminals brought out for star delta Expt.
Model : LOGO PLC (4 Relay O/P, 24V, Source / Sink digital I/P 8)
List of experiments supported
Study of components in electrical systems and their operations.
Study of Hold ON Contact Logic.
Study of interlocking contact logics with trip indication.
Study of DOL starter logic.
Study of Star-Delta Logic (Automatic/ Semi Automatic/Manual)
Study of phase reversal logic.
Study of Sequential logic to start motors in a process plant using timers & AApanel. Optional experiments with PLC.
Study of Earth Leakage Fault and Tripping Threshold.
Optionally : Study of other types of starter like Auto transformer, Rotor / Stator resistance, Phase angle controlled, VFD etc provided with additional panels.
Mechanical Dimensions/ Wt. 1165(L) x300(W) x 990(H)