House/Commercial Wiring Installation Trainer

House/Commercial Wiring Installation Trainer

SALIENT FEATURES

  • High Voltage Kirchoff voltage & current law trainer !
  • Aluminum profile sturdy Modular flat panel (table top) system, carrying various high voltage components housed in plastic enclosures (panel) to minimize shock possibility.
  • Input 3 phase DOL Starter panel (EMT1)

10 Shrouded Banana

  • 4 pole MCB of 415 V/4A.
  • DOL 9AContactor with 230V / 50 Hz / 11VACOIL .
  • Bimetallic thermal O/L relay with range 1.4A - 2.3A .
  • Green SBS5 socket is provided for extend earth.
  • FWD/REV, Star-Delta starter panel (EMT 4)

12 Shrouded Banana

  • FWD/REV, 3 pole 3 way switch with centre OFF, 6A/440V.
  • Star/Delta switch 3 pole, 3 way with centre OFF, 6A/440V.
  • DC voltmeter and DC ammeter panel (EMT 6A/B)

14 Shrouded Banana

  • DC voltmeter(0-300V)
  • DCAmmeter (0-5A) with polarity protection diode
  • Field failure relay to control Armature supply.
  • Instrumentation Power supply cum Multichannel DPM panel (EMT 8)
  • DC Multi Output power supply.
  • Supplies DC power to neighboring signal conditioning circuit panels like EMT9, CIP1, CIP2, MIT12, CE7 etc. through 20 pin FRC cable.
  • Provides 1 Ph. AC supply through 3 MCB's, 4A each to power up other panels in the rack.
  • Optionally Multichannel 4 position DPM for Speed, Torque etc
  • Green SBS5 socket is provided for extend earth.
  • SCR Actuator (variable DC) cum sensor signal conditioning panel (EMT9) x 3 Nos. [4 Shrouded Banana]
  • Full bridge SCR based 0V-195V / 3 Amp cosine firing with linear characteristics.
  • Supports signal conditioning circuit for speed, torque in kg wt to output 0-2.5Vdc (FS).
  • Resistor Load (EMT14A/B)
  • AC Resistors =10K/5K/3.5K/2.5K/2K/1.5K/OFF 200W x 3 phases/ 6 taps
  • DC Resistors = 750E / 600E / 300E / 212E / 162E / 125E / 112E / 100E / 400W / 8 taps + OFF + separate 60E tap for DC series Gen.

LC Load (EMT 15A/B) panel

  • Inductive load = 0.15H/0.3H/0.45H/0.6H/0.75H/
    CBT Labview based animation CD
  • Capacitive load =1.25u /2.5u/5u/415VX 3Nos.
  • 1 ph. Motor, Alternator & Sync. Motor Panel (EMT 16)
  • 1 ph. MCBs of 4A/1.6A 1 each.
  • 2 no. 2P2W selector switches to run as 1ph. alternator then as synchronous motor.
  • 8Apushbutton switch to simulate as centrifugal switch.
  • 3 Ph. Bidirectional power cum Energy meter panel (EMT20) [8 shrouded Banana]
  • Bidirectional Multifunction
  • 3 Phase ¾ wire, 415V CT Input 5A
  • LCD/LED display, Aux supply 230V, 45-65 Hz, 5W
  • V,I., Hz, Pf, KVA, KW,KWH
  • Modbus RTU RS 485 (optional)
  • Green SBS5 socket is provided for extend earth.
  • Integrated (1 Ph.) measurement panel (EMT 20F)

8 shrouded Banana

Consists of table top aluminium profile (45x45) strudy modular flat demo panel rack (4x3 matrix) system, holding various panels as below

  • Bidirectional Multifunction Meter
  • 3 Phase 3/4 wire, 415V, CT Input 5A
  • LCD/LED Display auto supply 230VAC 45-65Hz, 5W.
  • V.I., Hz, Pf, KVA, KW,KWH
  • Modbus RTU RS 485 (optional)
  • Green SBS5 socket is provided for extend earth.
  • Table Top Machines / accessaries :
  • 3 phase dimmer/variac 415V/3A/50Hz
  • CBT Labview based animation CD is supplied along with to facilitate easy understanding.

List of experiments

  • DC circuits fundamentals : Ohms Law, Resistors in series, parallel. Power in DC circuit, Kirchoff's voltage, current law, Thevenin's Theorem.
  • AC circuit fundamentals Single Phase : Sine wave alternating current, Voltage. Average RMS values, AC through inductance and power, series R-L circuit and power, series R-C circuit and power, series R-L circuit and power.
  • AC circuit fundamentals- Three Phase : Balanced three phase resistive load STAR /DELTAconnection

Business Channel Partners